New Year Special Sale Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: scxmas70

Note! Following NS0-520 Exam is Retired now. Please select the alternative replacement for your Exam Certification. The new exam code is NS0-521

NS0-520 Exam Dumps - NetApp Certified Implementation Engineer - SAN Specialist ONTAP

Go to page:
Question # 17

While expanding a 200 GB LUN in an ONTAP 9.4 system, the following error is observed:

What is the cause of this error?

A.

The volume auto-grow is disabled.

B.

The LUN reached maximum capacity.

C.

The LUN can be expanded up to 10 times its original size.

D.

Space reservation is enabled.

Full Access
Question # 18

You are planning to set up a new SAN with an AFF A300 2-node switchless cluster. Your SAN fabric will consist of Cisco MDS9148s switches.

According to NetApp best practices, which two actions would be required to accomplish this task? (Choose two.)

A.

Set the switchport speed setting to 16 Gb.

B.

Use single initiator, multiple target zoning.

C.

Use multiple initiator, single target zoning.

D.

Set the switchport speed to auto negotiate.

Full Access
Question # 19

You have an SVM that serves LUNs to your hosts in an FC SAN environment. This SVM runs on a 4-node cluster and has two data LIFs on each node, according to best practices. You just created a LUN and mapped it to your initiators group. The LUN is owned by node01.

In this scenario, what would be an appropriate test for LUN mobility?

A.

Move the LUN to node02.

B.

Mirror the LUN to another node in your cluster.

C.

Physically disconnect the SAN ports, and verify if the SAN data LIFs automatically move to other hosts.

D.

Copy the LUN to another node and create a new LUN map.

Full Access
Question # 20

Referring to the exhibit, which container gains space savings from deduplication, compression and compaction?

A.

the aggregate

B.

the qtree

C.

the volume

D.

the LUN

Full Access
Question # 21

Referring to the exhibit, you have SAN LUNs on an AFF A700s and are asked to test an SSD shelf stack failure.

What is the maximum allowed number of failed paths per controller to shelf stack before a storage failover occurs?

A.

1

B.

3

C.

2

D.

4

Full Access
Question # 22

The ESX host reports inconsistent performance for iSCSI-based connectivity.

In this scenario, what would cause this problem?

A.

The host and storage are connected to different switches.

B.

The flow control was disabled on the storage.

C.

The hardware initiators were used instead of software.

D.

The flow control is enabled on the storage.

Full Access
Question # 23

An administrator is configuring a SAN-only cluster. The data room that houses four AFF A220 controllers is small and not able to house the DS224C shelves. The administrator proposes to rack the shelves in a separate room that is 40 meters away from the controllers.

In this situation, how would you properly cable the controllers to the shelves?

A.

Use multimode passive optical cables.

B.

Use multimode active copper cables.

C.

Use multimode active optical cables.

D.

Use multimode passive copper cables.

Full Access
Question # 24

An administrator is configuring their Ethernet switches to support an AFF A300 cluster that will be providing iSCSI LUNs to servers. The switches are also used for other traffic from various hosts.

In this scenario, which statement about the switch configuration is correct?

A.

Use a larger MTU size at the SAN connection rather than the host connections to allow for greater SAN bandwidth.

B.

Use network ports as access ports only.

C.

Use multiple VLANs to segregate iSCSI traffic from other traffic types

D.

Use a single VLAN to consolidate all data traffic on the switches.

Full Access
Go to page: