Winter Sale Special Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: v4s65

150-820 Exam Dumps - Brocade Certified Ethernet Fabric Professional 2015

Go to page:
Question # 4

You have a four-switch Brocade VCS Fabric operating in fabric mode. You make an interface level configuration change on the principal switch.

Which statement is true?

A.

You need to commit the changes on the principal switch for it to be propagated to all other switches in the fabric.

B.

You do not need to commit the change on the principal switch for it to be automatically propagated to all the other switches in the fabric.

C.

You need to commit the change on the principal switch; the change will only appear on the principal switch and it will be persistent across a reload.

D.

You do not need to commit the change on the principal switch for it to appear on the principal switch; the change will be persistent across a reload.

Full Access
Question # 5

Exhibit:

switch# show port-channel 300

LACP Aggregator: Po 300 (vLAG)

Aggregator type: Standard

Ignore-split is enabled

Member rbridges: rbridge-id: 51 (2) rbridge-id: 52 (2)

Admin Key: 0010 - Oper Key 0010

Partner System ID - 0x8000,01-e0-52-00-00-02

Partner Oper Key 0010

Member ports on rbridge-id 51:

Link: Te 51/0/31 (0x19180E801C) sync: 1

Link: Te 51/0/32 (0x19180F001D) sync: 1

Exhibit:

Referring to the exhibit, what information is determined?

A.

The vLAG has four nodes.

B.

The primary port is on RBridge ID 51.

C.

The configured LAG type is static.

D.

All links on RBridge 51 are currently enabled and active.

Full Access
Question # 6

You need to deploy several FCoE initiators connected through a Brocade VDX 6730. You are required to add the VDX 6730 to an existing FC SAN without increasing the number of domains.

Which action is required?

A.

Configure the LSAN zones on the VDX 6730.

B.

Configure the VDX 6730 in Access Gateway mode.

C.

Configure the VDX 6730 in VCS Logical Chassis mode.

D.

Configure the VDX 6730 in stand-alone mode.

Full Access
Question # 7

You have a Brocade VCS Fabric and one Brocade VDX has the multicast root manually assigned with the highest priority. You are going to remove that VDX from the fabric.

Which switch will become the multicast root if no other device has the priority set?

A.

the principal switch

B.

the lowest RBridge ID

C.

the coordinator switch

D.

the highest RBridge ID

Full Access
Question # 8

You must determine where a specific virtual machine defined in a port profile is physically attached to the Brocade VCS Fabric.

Which action would you perform?

A.

Look at the port profile configuration.

B.

Look at the MAC address table.

C.

Look at the VCS Fabric configuration.

D.

Look at the LLDP table.

Full Access
Go to page: