Question # 4

Which three statements are true about the newest clock board redesign/ operation in a SPARC M5-32/M6-32 server?

A.

There are two clock boards in a redundant configuration, so the failure of the primary clock board does not cause a reboot of the server.

B.

There are two clock boards. Each has two clock sources, so if a clock source fails, the alternate clock source on the same board takes over.

C.

While the system is running on an active clock board, a faulty clock board can be replaceddynamically.

D.

There are two clock boards in a redundant configuration, and there is a dynamic failover of theprimary clock board to the standby clock board.

Full Access
Question # 5

A customer calls in and reports a problem with CMU#10. They said they have an issue with HOST1. What Domain Configurable Unit (DCU) is this board located in?

A.

DCU_0

B.

DCU_1

C.

DCU_2

D.

DCU_3

E.

DCU_4

Full Access
Question # 6

The service processor collects audit and event records. The records can be used to show when certain actions occurred on the SPARC M5-32 platform. Which two commands list the event and audit log entries?

A.

show /SP/logs/event/list

B.

show /System/Log/audit

C.

show /SP/logs/audit/list

D.

show /Servers/Log/list

Full Access
Question # 7

There are a total of 36 fan modules in the SPARC M5-32 server, and all are redundant and hot- swappable. Which statement is correct?

A.

Half of the 36x fan modules are located on the front and the other half on the rear. 18x fan modules are in front fan cages and 18x fan modules are in back fan cages.

B.

36x fan modules are located on the front and rear; 12x fan modules are in front fan cages, 12x fan modules are in back middle fan cages, and 12x fan modules are in back lower fan cages.

C.

All 36x fan modules are located on the front, 16x fan modules in upper fan cages, 16xfan

modules in lower fan cages, and 2x fan modules on each side (left and right next to the SP/SSB).

D.

All 36x fan modules are located on the front, 12x fan modules are In upper fan cages, 12x fan modules are in middle fan cages, and 12x fan modules are in lower fan cages.

Full Access
Question # 8

A customer wants you to create a user account for a night-shift employee to be able to monitor the system but do nothing else. Which privilege do you assign to this user?

A.

user (u)

B.

administrator (a)

C.

console (c)

D.

read-only operator (o)

Full Access