Black Friday Special Sale Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: scxmas70

DES-4122 Exam Dumps - Specialist - Implementation Engineer PowerEdge Version 2.0

Question # 4

An engineer needs to install an additional PSU on an existing, single PSU Dell EMC PowerEdge R740. They complete the initial installation and cabling procedures. They connect an AC cable and the power distribution unit produces normal AC output. The engineer checks power management and sees that the new PSU is in the Failed state.

What task should be completed to troubleshoot this issue?

A.

Confirm the System Input Power CAP is not set to Low

B.

Set the PSU AC redundancy to 1+1

C.

Set the PSU AC redundancy to 1+0

D.

Verify the new PSU is the same type and wattage rating

Full Access
Question # 5

You are Investigating a disk error on a Dell EMC PowerEdge server and discover a Hot Spare has not been assigned to the Virtual Disk Group. Use the simulator to assign the Global Hot Spare. When you have finished using the simulator, dick Next.

Full Access
Question # 6

A technician is sent on-site to troubleshoot a server that produced an error message during the most recent POST, but then completed the POST and booted to the operating system. The user cannot remember the specific error and no entry was made in the error log relating to this error.

How can the technician find out what the error message was?

A.

Access the Lifecycle Controller and view the last boot cycle video capture entry

B.

Reload the BIOS firmware

C.

Export the Server profile and analyze for any POST errors

D.

Access the iDRAC and view the last boot cycle video capture entry

Full Access
Question # 7

For a temporary migration task the CPU core count on the Dell EMC PowerEdge R640 server needs to be reduced to 8 because the installed application will not work due to license restrictions. Use the simulator to apply the change so the application can be installed.

When you have finished using the simulator, click Next.

Full Access
Question # 8

A system engineer has a 14G Dell EMC Poweredge server with an amber light blinking. The engineer must pull a SupportAssist collection before calling Dell Support to evaluate what the potential problem. Use the simulator to collect and view the SupportAssist collection.

Full Access
Question # 9

For security reasons, the Dell EMC PowerEdge server power button must be disabled. Use the System Setup Utility in the simulator to disable the power button. When you have finished using the simulator, click Next.

Full Access