A logging volume needs to be migrated to a new array.
Which command must be used to associate the distributed devices to the new logging volume?
During the installation of a VPLEX Local, the command ‘configuration system-setup’ is issued. What is accomplished by this command?
Which vplexcli command will ensure that the directors SSD firmware has been upgraded to the correct version after the VPLEX NDU ?
A customer wants to implement VPLEX between two datacenters 200 km apart. The latency between the sites is 15 ms.
Which VPLEX topology is recommended?
Click on the calculator in the upper left corner. How much distributed storage can be managed by a 20 GB logging volume?
What are the three components that a drill-down command can be run against to provide a more detailed analysis?
You are using VPLEX Unisphere to perform management functions in your environment. You are tasked with creating several volume migrations to a new storage array.
What tab should you use to perform this migration?
Refer to the exhibit.
During a short power disruption to cluster 2, director-2-1-A failed. Power was restored after 5 minutes. In examining the output of the vault status command, you note that cluster-2's status reads "Cluster is not vaulting/unvaulting".
Why did this message appear?
Refer to the exhibit.
Reference the message type shown at point "1". What type of response will be sent back to the SNMP management server from the SNMP Agent?
Refer to the exhibit.
What is the purpose of VPLEX Witness in a Metro environment?
A customer has a VPLEX Metro configuration across two data centers 200 km apart. During an overnight backup, the WAN-COM link between the two data centers fails.
Which volume allows for future incremental re-synchronization with the remote mirror once the link is restored?
You have added a new storage array to your environment, but VPLEX, does not see it. Which VPlexcli command will display the new storage array?
A customer wants to collect performance data for specific virtual-volumes and has created the performance monitor.
What step needs to be performed to enable data capture?
After an expansion of a RAID-0 device in VPLEX, the customer notices a slight degradation of performance. What could cause this?
You created a synchronous consistency group, which contains two distributed volumes configured with the rule "set cluster-1-detaches".
What is the expected behavior of the virtual volumes in the event of a WAN-COM failure?
What are the four basic dm migration commands for moving extents or devices?
Refer to the exhibit.
What does this 4-step VPLEX cache operation represent?
You need to claim storage that is presented to VPLEX from a VNX. What is required in order to create the mapping file needed by the VPLEX Claim Storage Wizard?
Refer to the exhibit:
Which two modules are used for back-end connectivity?
A customer has a VPLEX Metro with VPLEX Witness installed and configured. The detach rule for consistency group is "no-automatic-winner".
What will VPLEX Witness do in case of a Site 1 failure?
Refer to the exhibit.
You have opened the VPLEX Unisphere Manager to validate the health of the system.
What is the most likely reason for the Operational Status indicator?
What is the recommended protection to be used when creating a VPLEX Logging Volume?
Refer to the exhibit.
A customer has not followed EMC best practices when cabling their VS2 VPLEX engine. You are asked how to re-cable the engine to adhere to best practices. What is your response?
Refer to the exhibit.
You are planning to perform data mobility between VPLEX Clusters using the GUI. What mobility job options do you have?