Black Friday Special Sale Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: scxmas70

E20-526 Exam Dumps - XtremIO Solutions and Design Specialist Exam for Technology Architects

Question # 4

Which SCSI instructions are used to build a bitmap of the changes between the first snapshot and subsequent snapshots when RecoverPoint is used with XtremIO?

A.

SCSI Delta

B.

SCSI Transfer

C.

SCSI DIFF

D.

SCSI Update

Full Access
Question # 5

You are designing an XtremIO solution for a potential customer. If the server and storage information is available, which information should be documented regarding the customer’s capacity expectations?

A.

Capacity requirements on a per data center basis

Expandability/scalability

Performance requirements determined on a server-to-server basis

B.

Capacity requirements on a per volume basis

Expandability/scalability

Performance requirements determined on a server-to-server basis

C.

Capacity requirements on a per volume basis

Compression rates/scalability

Performance requirements determined on a server-to-server basis

D.

Capacity requirements on a per data center basis

Expandability/scalability

Performance requirements determined holistically

Full Access
Question # 6

What is the maximum speed of the Fibre Channel ports on an XtremIO storage controller?

A.

2 Gb/s

B.

4 Gb/s

C.

8 Gb/s

D.

16 Gb/s

Full Access
Question # 7

A customer’s storage administration team wants to receive e-mail notifications when the XtremIO cluster detects an issue of major seventy. The customer has successfully configured and tested the e-mail server in the XtremIO GUI. However, the e-mail server is not receiving the expected notifications when major severity issues appear.

What is the cause of this issue?

A.

Alert definitions have not been defined

B.

Event handlers have not been defined

C.

Public reports have not been defined

D.

Private reports have not been defined

Full Access
Question # 8

Refer to the exhibit.

A customer has a VMware Horizon View environment with the following characteristics:

  • One X-Brick XtremIO cluster
  • 100% read during a boot storm
  • 8K read/writes

What is the maximum recommended number of VDIs the XtremIO cluster can support during a boot storm?

A.

1625

B.

1833

C.

3250

D.

5094

Full Access
Question # 9

A customer is interested in purchasing XtremIO for their mission critical database applications that require the lowest possible response times. They have two data centers in which they want to introduce All-Flash arrays. However, they need a way to maintain true active/active access to all databases and application LUNs across both sites.

What is the recommended solution to address the requirements?

A.

ViPR Controller with XtremIO

B.

RecoverPoint with XtremIO

C.

VPLEX Metro with XtremIO

D.

ViPR SRM with XtremIO

Full Access
Question # 10

A customer is interested in transitioning their traditional infrastructure to the Cloud by implementing ViPR software-defined storage in an XtremIO environment. Which capabilities will EMC ViPR software-defined storage provide to XtremIO?

A.

Delivers SaaS

Centralized management and monitoring

Chargeback and billing capabilities

B.

Chargeback reporting capability

Centralizes reactive monitoring capability

Policy-driven configuration management

C.

Automatically grows storage volumes

Slows growth of data

Centralized auto-deletes of aging files

D.

Creates virtual storage pools

Automates disaster recovery

Replaces chargeback capabilities

Full Access