Question # 4

Which are the advantages of the optical switching topology relative to point-to-point and the arbitration ring? (Select 3 Answers)

A.

Multiple points can communicate at the same time

B.

each node failure is independent, single node failure will not affect the other nodes

C.

devices share the bandwidth

D.

support multiple transmission rate at the same time

Full Access
Question # 5

Analysis of SAN system IO path, when the path of the terminal controller RAID module to the DISK is abnormal, the system will let the end controller to deal with the IO by IBS channel, then IO path is longer, the performance will declinE.

A.

True

B.

False

Full Access
Question # 6

When do a rollback operation to the virtual snapshot, the source LUN of snapshot cannot be mapped to the operating system.

A.

True

B.

False

Full Access
Question # 7

Running df output on AIX ias follows:

# df /kyleFilesystem 512-blocks Free %Used Iused %Iused Mounted on /dev/hd2 16056320 1925384 89% 110034 100% /kyle

At this time, it can't create a file or folder in this /Kyle directory.

A.

True

B.

False

Full Access
Question # 8

UltraPath multipath software supports multiple network connection mode, and the most simple way of connecting method is directly connected network.

A.

True

B.

False

Full Access
Question # 9

HP-UX does not need to be installed UltraPath multipath software additionally, which can be realized the function of multipath through the own pv-link of the system.

A.

True

B.

False

Full Access
Question # 10

What are the common networking methods in SAN practical applications? (Select 2 Answers)

A.

IP SAN

B.

FC SAN

C.

SAS SAN

D.

ISCSI SAN

Full Access
Question # 11

In video monitoring business, RAID levels of the array recommend choosing RAID10, in order to achieve higher performance requirements.

A.

True

B.

False

Full Access
Question # 12

Multipath operation process is abnormal in Windows platform, which log files is suggested to main analysis?

A.

cfg file

B.

UPLOG_x.txt

C.

InstallationLog.txt file

D.

UPLOG.txt

Full Access
Question # 13

Which are the troubleshooting steps of fault diagnosis for iSCSi host link? (Select 3 Answers)

A.

check the indicator light of the host network ports, storage host port is normal or not

B.

checked whether there is any quality problem of network cable (replacement method)

C.

check the status of ISM interface iSCSI host port

D.

check whether the host can ping storage business IP and telent port is successful or not, such as Telnet IP 3620

Full Access
Question # 14

About LUN copy technology, which of the following statements are correct? (Select two Answers)

A.

the process of copy don't need to stop business

B.

only support LUNCopy based on IP network

C.

support dynamic change copy speed

D.

support third-party LUNCopy storage array

Full Access
Question # 15

Remote copy link between array according to transport protocol is divided into which several? (Select three Answers)

A.

parallel link

B.

cross link

C.

FC link

D.

iSCSI link

Full Access
Question # 16

Smart prefetching algorithm can dynamically analyze the current business IO randomness and the rule of the IO size, determine whether start-stop prefetching and setting up the prefetch window sizE.

A.

True

B.

False

Full Access
Question # 17

For snapshot , LUN copy and remote replication of storage array, which of the following statement is true? (Select 3 Answers)

A.

add resources LUN in resource pool, controller A and B both added and equal size, which is the best

B.

create LUN copy if confusing the source LUN and target LUN may result in data loss

C.

create remote copy if confusing the source LUN and target LUN may lead to the data unavailable

D.

if the space of the resource pools is insufficient, system will automatically use the residual capacity of safe space as a resource pool space

Full Access
Question # 18

For incremental LUN copy of storage array, which of the following is correct?

A.

it is real-time synchronization

B.

in the process of copy, target LUN can mount to use

C.

can be used in A-A backup mode

D.

the incremental LUN copy and LUN copy use public License

Full Access
Question # 19

Hyper replication technology of Storage array is usually based on block level of replication.

A.

True

B.

False

Full Access
Question # 20

The physical media which FC protocol support must be optical fiber.

A.

True

B.

False

Full Access
Question # 21

When HyperManager manage remote replication strategy, it can only manage synchronous remote replication.

A.

True

B.

False

Full Access
Question # 22

For S5000T storage array, if the source LUN of virtual snapshot belongs to controller A, and then the virtual snapshot can only use the source LUN of resource pool A.

A.

True

B.

False

Full Access
Question # 23

In FC arbitration ring architecture, when the device is join or exit, do not have effect on other devices of the ring.

A.

True

B.

False

Full Access
Question # 24

Ext3 file system only support the maximum partition of size 2T.

A.

True

B.

False

Full Access
Question # 25

Which of the following components do not belong to FC SAN network hardware?

A.

HBA card

B.

switches

C.

storage device

D.

server mainboard

Full Access
Question # 26

In the Linux platform, which of the following commands can be used to check the mapping which adds for the host on the array?

A.

iscsiadm -m node

B.

lsscsi

C.

rpm -qa︱grep iscsi

D.

fdisk -l

Full Access
Question # 27

On which component UltraPath multipath software is deployed in the network?

A.

OS server

B.

switch

C.

storage arrays

D.

storage virtualization platform

Full Access
Question # 28

A set of S5500 write policy set to write-back, after a controller lapsed, LUN's write strategies will translate into through.

A.

True

B.

False

Full Access
Question # 29

Which of the following HostAgent components need to restart the host after the installation is complete?

A.

HyperManager server

B.

InbandAgent

C.

ConsistentAgent

D.

HyperManager client

Full Access
Question # 30

In the process of the whole disk copy, RAID group is in normal condition, all member disks are in available state, data redundancy information of RAID group is complete, and the customer data has no risk of loss.

A.

True

B.

False

Full Access
Question # 31

About iSCSI protocol implementation of three parts, which describe are right? (Select three

Answers)

A.

initiator Portal: provide connection iscsi storage device and ISCSI packet parsing and the driver of data reading and writing.

B.

Target Portal: iscsi storage devices, provide data storage services

C.

Portal: by IP address and port (default of iSCSI is TCP3260), through the Portal to provide connectivity and services

D.

initiator Portal: iscsi storage devices, provide data storage services

Full Access
Question # 32

what are the main difference between optical fiber topology FC-AL and FC-SW? (Select three

Answers)

A.

topological structure of FC-AL is network, topological structure of of FC-SW is circular

B.

FC-AL use AL-PA query equipment, FC-SW use Name Server query equipment

C.

when there is new equipment join in, FC-AL need to interrupt network, FC-SW don't need to

interrupt the network

D.

FC-AL through the hub as connection device, FC-SW optical switches as connected devices

Full Access
Question # 33

What are the main functions of UltraPath multipath software? (Select 3 Answers)

A.

if there is no multipath software, it will not be able to configure the cluster

B.

failover

C.

the load balancing

D.

failback

Full Access
Question # 34

Incremental LUN copy about storage array, which of the following are correct? (Select two Answers)

A.

support third-party array to third-party array

B.

support huawei array to other manufacturers array

C.

support copy in S5000 and S2600 array

D.

don't support copy in S5000T and S5000 array

Full Access
Question # 35

Under Linux platform, the host message information is important log of the host-side fault diagnosis, among the logs collected by collecting tools HostInfoTools - 1.2 sh, which file is the message log?

A.

PROC. txt

B.

OS_TYPE_INFO.txt

C.

LOG_INFO.txt

D.

ARRAY_INFO.txt

Full Access
Question # 36

Under AIX platform, what command is to check the host mounts all devices?

A.

cfgmgr –v

B.

lspv

C.

lsdev -Cc disk

D.

rmdev -dl hdisk2

Full Access
Question # 37

Which does not belong to HostAgent component?

A.

HyperManager server

B.

InbandAgent

C.

ConsistentAgent

D.

HyperManager client

Full Access
Question # 38

Which of the following functions need to use the space of resource pool in storage arrays? (Select two Answers)

A.

asynchronous remote replication

B.

synchronous remote replication

C.

full dose LUN copy

D.

increment LUN copy

Full Access
Question # 39

For the storage array products, which of the following reasons will cause full amount LUN copy fault? (Select 3 Answers)

A.

the source LUN failure

B.

target LUN failure

C.

link failures

D.

there is insufficient space on the resource pool

Full Access
Question # 40

Substitution method is to use a normal part to replace a suspected abnormal part, so as to achieve the parts of the aim of locating faults and troubleshooting, can be a fiber optic jumper, a cable, a controller or a cascade modulE.

A.

True

B.

False

Full Access
Question # 41

For storage array LUN copy function, same LUN can't do multiple incremental source of LUN copy.

A.

True

B.

False

Full Access
Question # 42

Below the write Cache strategy description about the array is not the right are:

A.

write-through cache suggest mirror mode, in order to improve data reliability

B.

Write Back cache can improve SAN performance

C.

Write Back cache no matter whether to adopt the mirror, random write performance almost no difference

D.

write-through cache, bottle neck area of SAN performance often on the disk

Full Access
Question # 43

About the storage array, which LUN copy function is true? (Select two Answers)

A.

when create LUN copy , you can use one virtual snapshot of LUN as the source of LUN

B.

when create increment LUN copy, you can use external array as the source of LUN

C.

when create full capacity of LUN copy, the source of LUN and target of LUN can't be located in

the external array at the same time

D.

multiple LUN copy can share same target of LUN

Full Access