What is the range of the number of battery cabinets in the FusionModule800 module?
UPS5000-E only needs to select ( ), it can easily realize 2N power supply system, and the operation is simple and convenient. .
There is no need to charge additional refrigerant within the length ( ) meters of the connecting pipes between the internal and external units of the FusionModule800 temperature control system.
Which of the following functions does the PDU8000 precision power distribution cabinet have? (
The asset management in the NetEco management system can manage the asset information of which of the following devices to realize the life cycle management of assets? (multiple choice)
When configuring the cables of the UPS, it is necessary to consider the rated current of the UPS and the voltage drop on the line for selection.
FusionModule1000A V2R3 version 20-foot CT solution supports a maximum CT load of 8kW /
What kind of incoming and outgoing lines can be realized by the FusionModule2000 integrated power distribution cabinet?
The power systems of FusionModule800 and FusionModule500 are 380/400/415/3Ph/50Hz and 220/230/240/1Ph/50Hz respectively ()
A system is configured with a 5H battery backup time, and the discharge termination voltage of the battery cell should be selected from ()/
The Huawei Configurator can automatically configure the cable specifications and lengths from the head cabinet to the IT cabinet. ( ).
The NetCol 8000-C room-level chilled water intelligent temperature control product has parts that can be plugged and maintained online, which can greatly reduce the time for parts replacement.
()
Compared with high-frequency machines, industrial frequency machines may bring more additional investment, including: ()
NetEco. supports northbound integration, which of the following is not currently supported? ( ).
The fan of Huawei Precision Air Conditioner NetCol5000-C030 cannot be maintained online.
The static load of the FusionModule2000 cabinet can support 1800KG, which is the highest in the industry.
The following functions belong to the Fusionmodule2000 controller (ECC800) ( )
Huawei Netcol air-cooled air conditioner -- one indoor unit can correspond to multiple outdoor units ()
When choosing a 300mm air conditioner, you need to choose a 300mm control skylight ( )
UPS products such as APM and NXR need to be derated when the temperature is 30 degrees, and UPS5000-E does not need to be derated when the temperature is below 40 degrees.
The top of the FusionModule2000 cabinet can be installed with stainless steel bridge or M-type wire duct ().
The power supply architecture supported by the new room and air-cooled series is ()
FusionModule500&FusionModule800 remote WEB interface monitoring must be configured with unified network management software (
The UPS5000-E battery adopts the design of no neutral line, which is convenient for the battery to be used when replacing the tower.
The operating temperature range of FusionModule800 is -20~45 degrees, and the operating temperature range of FusionModule500 is 0~45 degrees /
The NetEco management system can provide the power distribution topology map function, which can realize the monitoring of the whole power distribution link from the mains introduction to the end of the rPDU.
FusionModule solution can use ECC800 to realize local monitoring, and use NetEco management system to realize centralized monitoring of multiple micro-modules. Then, in the project bidding
quotation, which product is the configuration quotation of the ECC800 collector in?
What is the lightning protection level of the integrated UPS of Fusionmodule2000? ( )
The UPS5000-E power module adopts the fan fault-tolerant design. When two of the fans are damaged, what percentage of the load can the power module still carry?
The new room-level air-cooled series is a full frequency conversion structure ( )
The operating temperature range of FusionModule800 is -40-45 degrees, and the operating temperature range of FusionModule500 is 0~45 degrees (
NetCol8000-A013U 13kW small cooling capacity temperature control product adopts DC inverter compressor
The access control management function of the Netco6000 management system only supports one-way card swiping (you need to swipe your card to enter the door, and press the exit button to go out), but do not support two-way card swipe (you need to swipe your
card to enter the door and go out).
The brand of EC fan used in the NetCol5000-A025H half-cabinet row-level inverter air-cooled precision air conditioner indoor unit is Xerox.
The NetEco management system supports the function of user decentralization and domain division, so that different operation and maintenance personnel can only view the devices they manage. For example, by assigning permissions, an
operation and maintenance personnel can only view the equipment information of the computer rooms of several outlets.
Are the Fusion Module500&Fusion Module800 air conditioners connected to the back end of the UPS? ( ).
The UPS5000-E battery adopts the design of no neutral line, which is convenient for the battery to be used when replacing the tower.
Which of the following functions or components does the UPS5000-E (50kVA power module) come standard with? ( )
PDU8000 precision power distribution cabinet supports single input and dual input
The maximum output power of UPS5000-E (25-75kVA) bypass module is 128kW. (
The NetEco6000 management system can provide monitoring of the cooling power system, and which of the following functions can be provided? (
The aisle type of the typical configuration of FusionModule800 is cold aisle?
Huawei Netcol air-cooled air conditioner requires low temperature components when the outdoor temperature is lower than -20"C ()
FusionModule1000A V2R3 version 40-foot IT scene can provide the number of cabinets (multiple choice)
The smoke sensor used in the NetEco6000 management system cannot replace the smoke sensor in the fire protection system. ( ).
The characteristics of UPS5000-A-400/500K in terms of ease of use, which of the following are correct
The minimum floor height of the computer room required by FusionModule2000 is 2.6 meters.
Using UPS5000-E (50kVA power module), the actual load is 160kW, the rack 1+1 redundancy, the single-machine backup power scheme is adopted, the backup power scheme for each machine, each rack has 3
sets of batteries, each set of 40 cells, The main switch box capacity is (
Configure the UPS system plan, which of the following factors need to be considered in the calculation plan: ()
Regarding the overload capacity of UPS5000-E, which of the following statements is correct?
Huawei NetGol (35KW) in-row air conditioner adopts wet film humidification function ( )
FusionModule2000 sensor adopts PoE ring network power supply to improve the reliability of signal transmission in the control system, and can be used for target control.
The maximum number of cabinets supported by a single module of FusionModule2000 is (
UPS5000-E (50kVA module) series UPS does not derate backup power, the number of 12V batteries in the following configuration, ( ) is unreasonable
Among the following models, the one with the widest input frequency range is ()
The type of humidifier adopted by the row-level chilled water intelligent temperature control product NetCol5000-C032H is ( )
What kind of circuit breaker is used in the main circuit of PDU8000 precision power distribution cabinet: ( ).
In UPS, corresponding to 50k modules, the maximum output capacity of a single UPS is
When configuring temperature control products, if the temperature of the project location is -10 "30 °C, which of the following working conditions should be preferred
Which of the following certifications has the PDU8000 precision power distribution cabinet passed: (multiple choice)
Load 120kW, use UPS5000-S to meet N+2 modular redundancy configuration, can be configured ( ) kVA models+
Regarding the intelligent battery management in UPS5000-A, the following statement is correct ()
Which of the following statements about micromodules is true? (multiple choice)
In UPS5000S, the adjustable range of the number of battery cells in a single group is
FusionModule2000 can be configured with inter-column temperature control products ( ).
Using UPS5000-E (50kVA power module), the actual load is 160kW, the rack 1+1 redundancy, the single-machine backup power scheme is adopted, each rack has 3 groups of batteries, each group is 30, and the
capacity of the main switch box is ( )
FusionModule1000A V2R3 version supports operation and maintenance methods (multiple choices)
Which of the following statements are true about the iBattery battery management system? ()
FusionModule2000 product configuration framework, including which of the following (
When the NetCol8000-C room-level chilled water intelligent temperature control product is booted, our ( ) model will be used first.
UPS5000-E about the characteristics of intelligence, which are correct? ()
UPS5000-E (50kVA module) series UPS does not derate backup power, the number of 12V batteries in the following configuration, ( ) is unreasonable. /
Regarding the cabinet rPDU of Fusionmodule2000, which of the following statements is wrong? ( )
UPS5000-E has a wide voltage and frequency input range, which can adapt to harsh grid environment and prolong battery life. What is the maximum input voltage range of
UPS5000-E? ( )
The maximum IT power supported by the precision power distribution cabinet of Fusionmodule2000 is ( )
If the FusionModule800 adopts the lower pipe, what is the minimum raised floor height?
UPS5000-E can easily realize N+X power supply system by only selecting ( ) , and the operation is simple and convenient. .