Black Friday Special Sale Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: scxmas70

INSTC_V7 Exam Dumps - BICSI Installer 2 - Copper Exam

Question # 4

Which of the following markings indicates that the cable is designed for use in a plenum space?

A.

CMR

B.

CMUC

C.

CMP

D.

CMX

Full Access
Question # 5

What is the maximum permissible amount of untwisting for category 5e cable and higher?

A.

12.7 mm (0.5")

B.

25 mm (1")

C.

38 mm (1.5")

D.

75 mm (3")

Full Access
Question # 6

How far should the top of a ladder extend above the roofline?

A.

0.3 m (1')

B.

0.5 m (1.6')

C.

0.6 m (2')

D.

0.9 m (3')

Full Access
Question # 7

What is the characteristic impedance of Series-6 coaxial cable?

A.

25 ohms

B.

50 ohms

C.

75 ohms

D.

100 ohms

Full Access
Question # 8

Which type of optical fiber cable should be color coded with a RED outer cable sheath?

A.

Dispersion-shifted SM optical fiber

B.

MM optical fiber with 50 um core diameter (laser-optimized)

C.

Polarization maintain SM optical fiber

D.

MM optical fiber with 50 um core diameter

Full Access
Question # 9

Which of the following fire ratings refers to the time period that the unexposed surface of a firestop assembly does not exceed 180 degrees C (325 degrees F) above its initial temperature?

A.

E rating

B.

FT rating

C.

FH rating

D.

S rating

Full Access
Question # 10

Unqualified workers must stay AT LEAST ____ from exposed energized conductors operating at 300 to 50,000 V.

A.

0.3 m (1')

B.

3 m (10')

C.

15 m (50")

D.

30 m (100')

Full Access
Question # 11

What is the minimum number of consolidation points that should serve an open office furniture cluster?

A.

1

B.

2

C.

3

D.

4

Full Access
Question # 12

A third 90-degree bend may be permitted in a conduit run if the run does NOT exceed ______?

A.

5 m (16.5')

B.

10 m (33')

C.

15 m (50')

D.

30 m (100')

Full Access
Question # 13

Which of the following is a building-serving space that houses large pieces of common active equipment?

A.

TR

B.

ER

C.

TE

D.

Mechanical Room

E.

Battery room

Full Access
Question # 14

What is the minimum inside bend radius for balanced twisted pair (multi-pair) cable?

A.

25 mm (1")

B.

50 mm (2")

C.

6 times the outside cable diameter

D.

10 times the outside cable diameter

Full Access
Question # 15

Which of the following tools is a low-cost cable verifier that can be used to test for opens, shorts, crossed pairs, and miswires in 4- pair cables?

A.

Wire map tester

B.

Qualification tester

C.

Telephone test set

D.

TDR

Full Access
Question # 16

Which of the following components is used to bond the electrical system's grounding electrode system to the PBB?

A.

RBB

B.

BBC

C.

TBB

D.

TBC

Full Access
Question # 17

What is the primary purpose of firestopping?

A.

Increase a facilities ability to detect fires

B.

Reestablish the barrier's fire rating

C.

Restore the barrier's original load-bearing capacity

D.

Suppress fires before they can spread

Full Access