Winter Sale Special Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: v4s65

AD01 Exam Dumps - Blue Prism Accredited Developer Exam

Go to page:
Question # 9

Which of the following Stages can be found in Process Studio AND Object Studio?

A)

B)

C)

D)

A.

Option A

B.

Option B

C.

Option C

D.

Option D

Full Access
Question # 10

Please refer to the exhibit.

A Developer has used the Win32 mode lo spy the login window and the Region mode to spy the Username field of a Windows-based application.

Using the Navigate stage, the developer would like to

* Bring the application screen to bring it foreground

* Send a 'Global Mouse Click Centre' command to the center of the username field

* Use Global Send Keys to populate the username field

How should the navigate stage be configured?

A)

B)

C)

D)

A.

Option A

B.

Option B

C.

Option C

D.

Option D

Full Access
Question # 11

Examine the following Blue Prism Action diagram taken from Object Studio:

What is wrong with the current configuration?

A.

The current configuration risks creating an infinite loop.

B.

The current configuration is missing an intelligent Wait stage after the 'Read Result Table' stage, to ensure the Action logic has worked correctly.

C.

There is nothing wrong with the current configuration.

D.

The Exception Block should be removed from the page so that all exceptions on that page can be recovered.

Full Access
Question # 12

When building a solution to use Tags within a Work Queue, which of the following statements is correct true?

A.

Adding a tag requires an item to be locked

B.

Adding a tag requires an item to be locked if there are multiple resources working the same queue

C.

Adding a tag does not require an item to be locked

Full Access
Question # 13

An Action called ‘Get Customer Address’ fails immediately and the following Exception is raised:

Internal: Stage Address Type does not exist

What is the potential reason for this Exception?

A.

An Action stage with the name 'Address Type' is being referenced but it no longer exists

B.

An internal error always indicates a problem with the Blue Prism product. The Blue Prism support team should be contacted for assistance

C.

A data item referenced as an input parameter in the 'Get Customer Address' Action cannot be found

D.

Whilst debugging a Process in Process Studio, the 'Reset' button was pressed whilst the process was calling the 'Get Customer Address' action

Full Access
Question # 14

You identify an element in Application Modeller and it highlights uniquely and can be used in your object flow diagram. The next day you find that Blue Prism cannot no longer identify the same element, your object flow is giving you 'Element not found' exceptions. Which of the following statements is true?

A.

This must be an environment issue. The Blue Prism environment must be consistent and persistent, and an element that worked one day and does not work the next day suggests the environment is changeable. The IT team supporting the environment needs to be contacted to fix the problem.

B.

The Blue Prism product support team should be contacted to report the issue. This signifies an inconsistency in how the Blue Prism product is working which needs to be fixed.

C.

This suggests that Best Practice exception handling has not been implemented in the object. A retry loop around the object stages that are using the element will probably fix the problem

D.

It is common for consistency issues to be found during configuration/development testing. The most likely cause is that an attribute has been selected for the element that is changeable, such as a window title with a date, or a URL The developer needs to ensure that any changeable attributes are unticked.

Full Access
Question # 15

Examine the following Page of a Blue Prism Process:

The expressions of each of the Calculation stages are provided below:

What will the value of the Result Data Item be after the page has run?

A.

Result Data Item value will equal A

B.

An Internal Exception will be thrown

C.

Result Data Item value will equal C

D.

Result Data Item value will equal B

Full Access
Question # 16

Please refer to the exhibit.

What is incorrect in the Object design"?

A.

The Recover Stage should be an Alert Stage

B.

A Resume Stage is missing

C.

A link cannot go to a Recover Stage

D.

No conditions exist for the Wait Stage

Full Access
Go to page: