Question # 4

( ) is the control component of doors in module data center.

A.

Access Actuator

B.

Multi-functional sensor

C.

Skylight actuator

D.

Rack Environment unit

Full Access
Question # 5

After all the NetEco monitoring cables are connected, users need to check ( ).

A.

Power cables and signal cables are bound separately.

B.

Proper redundancy is reserved at connectors of signal cables.

C.

Signal cable connectors are intact.

D.

Proper redundancy is reserved at the turning point for signal cables.

Full Access
Question # 6

By setting the mailbox parameters, the NetEco system will send an email to notify the user according to the set rules.

A.

TRUE

B.

FALSE

Full Access
Question # 7

On the NetEco, the door name can’t be modified.

A.

TRUE

B.

FALSE

Full Access
Question # 8

The NetCol5000-A25 kW supports light load dehumidification.

A.

TRUE

B.

FALSE

Full Access
Question # 9

( ) can connect to the AI/DI port on the access actuator.

A.

IC card reader

B.

Fingerprint and card reader

C.

Exit button

D.

Magnetic

Full Access
Question # 10

The height of the ECC800 collector is () U.

A.

1

B.

2

C.

3

D.

4

Full Access
Question # 11

NetCol5000-Acompressor discharge high pressure alarm occurs, it may not that ().

A.

The outdoor fan fails to start

B.

The outdoor fan is running at low speed

C.

The refrigerant is overfilled.

D.

The refrigerant is insufficient.

Full Access
Question # 12

FusionModule1000A series solution meets the TIER 4 requirements if it adopts 2N power supply and distribution system.

A.

TRUE

B.

FALSE

Full Access
Question # 13

Which are the high reliability features of NetCol5000-C?

A.

The internal pipes are wrapped with thermal insulation foam

B.

Condensate water can be drained by water pump or nature drain pipe.

C.

Internal cabling water pipe and electrical control part are deployed at return air side

D.

Water is

Full Access
Question # 14

NetCol5000-A eliminate partial hot spots by in-row cooling.

A.

TRUE

B.

FALSE

Full Access
Question # 15

DOD is the ratio of discharge battery capacity to the rated battery capacity, expressed as a percentage.

A.

TRUE

B.

FALSE

Full Access
Question # 16

If IP21 component is configured, top cable routing is not supported for UPS5000-E.

A.

TRUE

B.

FALSE

Full Access
Question # 17

Batteries in the same battery string must have the same capacity, same specifications and the same manufacturer.

A.

TRUE

B.

FALSE

Full Access
Question # 18

For NetCol5000-A, if a meter detect that no current passes through the infrared humidifier, it indicates that the lamp is damage.

A.

TRUE

B.

FALSE

Full Access
Question # 19

NetEco allows users to select alarm tones for different severities of alarms.

A.

TRUE

B.

FALSE

Full Access
Question # 20

The input frequency range of the UPS5000-E is () Hz.

A.

40-70

B.

45-70

C.

50-60

D.

55-65

Full Access
Question # 21

During filling refrigerant for NetCol5000-A, there is no need to put the refrigerant steel cylinder upside down on the electronic balance.

A.

TRUE

B.

FALSE

Full Access
Question # 22

Every time NetCol5000-C startup, settings values need to be reset.

A.

TRUE

B.

FALSE

Full Access
Question # 23

FusionModule1000 is an indoor prefabricated all in-one data center solution.

A.

TRUE

B.

FALSE

Full Access
Question # 24

When excessive dust blocks up the air filter, the air filter differential pressure switch will generate alarm.

A.

TRUE

B.

FALSE

Full Access
Question # 25

First time powering on UPS5000-E, make sure that the UPS main input switch, bypass switch, output switch, maintenance bypass switch and battery switch are all OFF

A.

TRUE

B.

FALSE

Full Access
Question # 26

Depending on different layouts, the batteries can be deployed inside or outside FusionModule2000

A.

TRUE

B.

FALSE

Full Access
Question # 27

When installing the power line on the UPS5000-E, if there are different sources on the main-lines and bypass, you need to remove the copper bars connected to the bypass and main lines first, and then connect the main circuit and bypass input respectively.

A.

TRUE

B.

FALSE

Full Access
Question # 28

Whether the water distribution unit is equipped or not is based on installation scenarios

A.

TRUE

B.

FALSE

Full Access
Question # 29

On the Current Alarm page of NetEco, filter criteria can’t set to search for the required alarms.

A.

TRUE

B.

FALSE

Full Access
Question # 30

Modular Data Center is on-demand deployment, which avoids over-investment.

A.

TRUE

B.

FALSE

Full Access
Question # 31

The UPS5000 option temperature and humidity sensor does not support cascading

A.

TRUE

B.

FALSE

Full Access
Question # 32

For NetCol5000-A installation, the required time of preserving positive pressure is ( ) hours.

A.

8

B.

12

C.

24

D.

16

Full Access
Question # 33

Two UPS2000-G with different software version can be connected in parallel.

A.

TRUE

B.

FALSE

Full Access
Question # 34

Users can log in the WEBUI of the ( ) to monitor the module data center.

A.

Water sensor

B.

ECC800

C.

Electronic lock

D.

Skylight actuator

Full Access
Question # 35

If a fire occurs in the FusionModule1000, the smoke detector and heat detector will send a fire alarm to the fire alarm control panel.

A.

TRUE

B.

FALSE

Full Access
Question # 36

Which component can control the light and charge a pad in FusionModule2000?

A.

Access actuator

B.

AC actuator

C.

Skylight actuator

D.

Smart ETH gateway

Full Access