Winter Sale Special Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: v4s65

HPE0-S60 Exam Dumps - Delta - HPE Compute Solutions

Go to page:
Question # 17

Which compute node parameters are captured within server hardware type?

A.

Number of the CPUs

B.

installed operating system

C.

Mezzanine card configuration

D.

Size of the memory Installed

Full Access
Question # 18

Which statement about an HPE Oneview support dump is true?

A.

Appliance support dump by default contains a logical enclosure support dump

B.

Support dump is a binary file that can be opened only in a dedicated application

C.

Support dump can be created if HPE Virtual Connect modules are installed in the frame

D.

Preview support dump is available only when creating an appliance support dump

Full Access
Question # 19

Your customer has an HPE Synergy platform deployed and managed using HPE OneView. The customer also has HPE Superdome Flex with RMC deployed They plan to deploy a second nPar and HPE Superdome Flex 280 They plan to manage new components using HPE OneView

What must be done to achieve this goal?

A.

The customer must use IL05 to add HPE Superdome Flex systems to HPE OneView

B.

The customer should deploy an HPE OneView appliance for HPE Superdome Flex management

C.

The customer must add a second Rack Management Controller for HPE Superdome Flex 280

D.

The customer has to add HPE Superdome Flex to the HPE OneView used to manage HPE Synergy

Full Access
Question # 20

Your customer plans to deploy a VMware ESXi with HPE Synergy platform. They also plan a vSAN deployment leveraging HPE D3940 Storage Modules and SSD drives

The customer requested the following components:

- HPE Synergy frame with ten HPE Synergy 480 Gen10 Plus compute modules

- Two HPE Virtual Connect SE 100Gb F32 Modules for Synergy

- An appropriate number of vSAN Standard licenses for each compute node

- One HPE O3940 Storage Module with 40 SSDs - All required cables and options

Which statement about this request is true?

A.

vSphere licenses should be added, as vSAN licenses do not replace vSphere licenses

B.

vSphere Standard licenses should be replaced with Enterprise Plus licenses to enable vSAN

C.

One HPE Virtual Connect SE 100Gb F32 Module for Synergy should be replaced with 50GD/S ILM

D.

20 SSD drives should be removed from this setup, as D3940 supports only 20 SSD or SAS drives.

Full Access
Question # 21

Your customer plans to manage HPE Primera using HPE Oneview

Which storage management tasks can be completed using HPE OneView for this environment?

A.

CPG management

B.

Volume provisioning

C.

Cache management

D.

Replication setup

Full Access
Question # 22

You need to configure a RoCE network to enable lossless networking for HPE J2000 Flash Enclosure support Which interconnects are required to support this connection? (Select two.)

A.

HPE Virtual Connect SE 40Gb F8 Module for HPE Synergy

B.

HPE Virtual Connect SE 16Gb FC Module for HPE Synergy

C.

HPE Virtual Connect SE 100Gb F32 Module for HPE Synergy

D.

HPE Virtual Connect SE 32Gb FC Module for HPE Synergy

E.

Brocade 16Gb Fibfe Channel SAN Switch Module for HPE Synergy

F.

Brocade 32Gb Fibre Channel SAN Switch Module for HPE Synergy

Full Access
Question # 23

You are troubleshooting an HPE OneView server profile that presents a critical state. The server profile was configured with a Link Aggregation Group

What should you check to fix the issue?

A.

if both FiexNICs are configured with the same speed

B.

If the logical enclosure is built on at least three HPE Synergy frames

C.

if both FiexNICs are connected to different networks

D.

if the logical enclosure is configured with redundant master modules

Full Access
Go to page: