Question # 4

What is a limitation when creating a server profile?

A.

BIOS settings can be changed only when UEFI optimized is selected as boot mode

B.

ILO management is limited to the integration with Active Directory or LDAP

C.

Administrator cannot define more than 8 connections within a server profile

D.

It is not possible to create shared volumes on demand through a server profile

Full Access
Question # 5

Your customer needs to move an application from an HPE Synergy 480 Gen10 Compute Module to an HPE Synergy 660 Gen 10 Compute Module. The 480 has a switch that has been manually zoned outside of HPE OneView.

What must the customer do before migrating the application?

A.

Migrate the application to a Logical JBOD and connect it to the new server

B.

Copy the server profile and assign the clone to the new hardware

C.

Edit the server profile and change server hardware type

D.

Create a new server profile template and apply to the new hardware

Full Access
Question # 6

The proposal consists of.

- 3 HPE Synergy 12000 frames

- 6 HPE Composer 2 modules

- 2 HPE Virtual Connect SE 100 GO F32 Module

- 4 HPE Synergy 50 GO interconnect Link Module

Which statements about this proposed design are true? (Select two.)

A.

The selected interconnect modules do not provide the requested WWN virtualization

B.

HPE Synergy 50Gb ILMs must be replaced with HPE Virtual Connect SE 100 GO F32 modules

C.

The current setup can support up to 18 HPE Synergy 480 Gen10 Plus compute modules

D.

FC upgrade licenses for HPE Virtual Connect SE 100 GbF32 Module must be added

E.

Remove 4 HPE Composer 2 modules from the design, as they are not required

Full Access
Question # 7

Your customer plans to setup an HPE Synergy solution based on SY480 Gen10 compute nodes with the following connectivity options - SAS connectivity installed in the first fabric - FC connectivity Installed In the second fabric - Ethernet connectivity installed in the third fabric.

Which statement regarding this setup is true?

A.

Each compute node must have at least 768GB of memory installed

B.

Interconnect modules that provide SAS connectivity should be moved to the third fabric

C.

Each interconnect module in each fabric must be properly licensed in HPE OneView

D.

Compute nodes must have a second CPU installed to access the second fabric.

Full Access
Question # 8

Your customer experienced some problems caused by outdated HPE Superdome Flex firmware. Which update method should they use to avoid these issues in the future?

A.

HPE OneView method for I/O firmware update procedure

B.

RMC CLI to update I/O and HPE Persistent Memory firmware

C.

HPE OneView IT HPE Persistent Memory firmware must be updated.

D.

HPE SUM if HPE Persistent Memory firmware must be updated