New Year Special Sale Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: scxmas70

NCS-Core Exam Dumps - Nutanix Certified Services Core Infrastructure Professional (NCS-Core 6.8)

Go to page:
Question # 41

An administrator receives a notification that storage in a Nutanix cluster is unavailable. The cluster consists of five nodes and is configured with a Fault-Tolerance level of 1 (FT-1).

Upon investigation, the administrator finds the following:

• All AHV hosts are powered on and the CVMs are running

• Nodes A, B, and C are connected to one top of rack switch

• Nodes D and E are connected to a second top of rack switch

• The cluster status command run on Node A shows that CVM services on nodes D and E are down

Which issue is causing the storage outage?

A.

The default gateway for the CVMs and AHV hosts is down.

B.

The switch connecting Nodes D and E is down.

C.

The genesis process is down on both Nodes D and E.

D.

Nodes D and E are in maintenance mode.

Full Access
Question # 42

An administrator needs to replace the self-signed certificate on a cluster. Which two requirements must be met as part of the process? (Choose two.)

A.

The cluster administrator must restart the interface gateway.

B.

The signed, intermediate and root certificates are chained.

C.

The existing certificate must be deleted prior to replacement.

D.

The imported files for the custom certificate must be PEM encoded.

Full Access
Question # 43

A customer has a Nutanix cluster with 10Gb connectivity via switch fabric extenders. The administrator receives NCC health check errors of latency greater than 200ms.

Which action should the administrator take to resolve the NCC errors?

A.

Replace the switch fabric extenders with 10G line rate switches

B.

Upgrade NCC and increase the CVM memory by 4Gb

C.

Add 2 additional 10G uplinks from the switch fabric extenders per node

D.

Upgrade NCC and increase the vCPU of the CVM

Full Access
Question # 44

During a technical call with a customer, it is identified that this installation will be software only on Dell servers. The out-of-band management interfaces will not be given IP addresses until the consultant is onsite.

Which Foundation method should be used for this type of installation?

A.

Bare metal using iDRAC MAC addresses.

B.

Bare metal using LAN MAC addresses.

C.

Bare metal using block serial numbers.

D.

Bare metal using node serial numbers.

Full Access
Question # 45

A consultant deploys a four-node VMware ESXi cluster and vCenter server. An HA/DRS cluster is configured for all four nodes. The customer deploys five new VMs on the cluster.

During the knowledge Transfer, a network cable on one node is removed to demonstrate HA and migration of the VMs to another host. In the HA/DRS cluster settings, the VM Restart Priority for all CVMs is set to Disabled. The customer observes warnings that the CVM on the ejected host is no longer powered on.

Which ESXi HA/DRS cluster setting is missing?

A.

Enable EVC for the cluster.

B.

Disable VM Monitoring on all CVMs.

C.

Disable Automation Level on all CVMs.

D.

Enable Host Monitoring.

Full Access
Question # 46

An administrator receives an alert in Prism indicating that interface eth2, on an AHV host is receiving many CRC errors. After togging into the problematic host, the following command is run to show the indicated output:

What is causing this issue?

A.

Incorrect link speeds on the switch

B.

The interface is incorrectly configured with Jumbo Frames

C.

A misconfigured bond

D.

A physical layer network problem

Full Access
Question # 47

A customer has two mission-critical applications and needs to have them backed up to a remote location. The remote location is connected using a leased line and has an average latency of 7 ms.

Which Nutanix technology will provide the shortest RPO possible?

A.

NearSync

B.

Leap

C.

Metro Availability

D.

Asyn&DR

Full Access
Question # 48

After an onsite cluster deployment, a consultant prepares the deliverables for a project closeout.

Which two data in the As-Built Guide require adjustment or might be missing completely? (Choose two.)

A.

Nutanix Node Port Layout

B.

AHV Host information

C.

Physical Rack Layout

D.

Cluster information

Full Access
Go to page: