A technician needs to replace two RAID controllers on a database server as part of an upgrade. The server has six external storage arrays and eight internal disks that are controlled by the two RAID controllers. The technician completes the replacement and powers the systems back on, but the server OS detects several missing disks in the configuration. Which of the following steps should the technician take first to resolve this issue?
IDS alerts indicate abnormal traffic patterns are coming from a specific server in a data center that hosts sensitive data. Upon further investigation, the server administrator notices this server has been infected with a virus due to an exploit of a known vulnerability from its database software. Which of the following should the administrator perform after removing the virus to mitigate this issue from reoccurring and to maintain high availability? (Select three).
A user is unable to access the database server from a workstation. All other workstations are able to access the database server. The technician issues the following command to check the workstation:
userGhost:!# nmap localhost
Nmap scan report for localhost (127.0.0.1)
Host is up (0.001 ms latency).
Not shown: 1023 closed ports
PORT STATE SERVICE
3306 open mysql
Which of the following should the technician perform next to allow access?
A server administrator notices drive C on a critical server does not have any available space, but plenty of unallocated space is left on the disk. Which of the following should the administrator perform to address the availability issue while minimizing downtime?
A server technician is placing a newly configured server into a corporate environment. The server will be used by members of the accounting department, who are currently assigned by the VLAN identified below:
Which of the following IP address configurations should the technician assign to the new server so the members of the accounting group can access the server?
A technician is configuring a server that will need to accommodate a planned network upgrade. All hosts will be changed from 10Gb copper to 25Gb fiber. Which of the following would best suit the requirements?
A technician is configuring a new server with four disks for the development team. The requirements are disk redundancy and maximum usable disk capacity. Which of the following RAID levels should be used for this server?
A Windows server has experienced a BSOD, and the administrator needs to monitor thereboot. The server is in a datacenter with no OOB management. Which of the following tools should the administrator use to complete this task?